What It Means
High Discharge Pressure
Likely Causes
- High ambient temperature (above 105°F)
- Dirty condenser coil (evaporator)
- Low water flow through heat exchanger
- Refrigerant overcharge
Next Checks
- Clean evaporator coil fins
- Check water flow rate through heat pump (need min 20 GPM)
- Ensure no restrictions on water side unions
- Normal above 105°F ambient — wait for cooler conditions
Verify Before Repair