What It Means
Flow Error / No Water Flow
Likely Causes
- Pump not running
- Flow switch failed
- Insufficient flow (< 20 GPM typically)
- Closed valves
- Dirty filter
- Air in system
Next Checks
- Verify pump is running and primed
- Check all valves are open
- Clean filter
- Minimum flow rate per spec sheet
- Test flow switch continuity
- Bypass flow switch temporarily to diagnose (pro only)
Verify Before Repair