What It Means
Pump Won't Start
Likely Causes
- GFCI tripped (most common cause)
- Breaker tripped
- Capacitor failed on single-phase motors
- No 240V supply at motor terminals
Next Checks
- Check and reset GFCI protection at outlet or subpanel
- Check main breaker — reset if tripped
- Test supply voltage at motor terminals (240V expected)
- Inspect and replace start/run capacitor if motor hums but won't start
Verify Before Repair