What It Means
Low Or Uneven Water Feature Flow
Likely Causes
- Feature valve partly closed
- Dirty filter or low pump speed
- Nozzle clogged
- Air leak on suction side
- Multiple features not balanced
Next Checks
- Open/adjust feature valve and increase pump RPM
- Clean filter and pump basket
- Remove and flush nozzles or laminar screens
- Balance each feature valve one at a time
- Check for air in pump basket indicating suction leak
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.
SplashLens is independent and is not affiliated with Water Features / Valves / Actuators or other equipment manufacturers.
Use SplashLens At The Pad
Manual error-code lookup works after the app has loaded once. AI scan features require internet and should be treated as a second set of eyes.