What It Means
Actuator Turns Wrong Direction
Likely Causes
- Toggle switch set opposite desired direction
- Cams adjusted incorrectly
- Valve mounted 180 degrees from expected orientation
Next Checks
- Use actuator toggle switch to reverse direction if appropriate
- Mark original cam positions before adjustment
- Adjust open/close cams in small steps
- Verify automation labels match actual valve function
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.