What It Means

Ignition Failure Lockout

Likely Causes

Next Checks

  1. Check gas supply shutoff is fully open
  2. Verify gas pressure at manifold
  3. Clean flame sensor rod with fine steel wool
  4. Inspect hot surface igniter — replace if cracked or not glowing
  5. After 3 failed ignition attempts unit locks out — hold Reset button to clear

Verify Before Repair

SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.