Sta-Rite AFS: Air Flow Switch Open

Sta-Rite AFS reference for Sta-Rite MAX-E-THERM / MASTER TEMP Gas Heater: likely causes, next checks, and manual-verification reminders for pool service techs.

Sta-Rite Sta-Rite MAX-E-THERM / MASTER TEMP Gas Heater HIGH Certified tech recommended

What It Means

Air Flow Switch Open

Likely Causes

Next Checks

  1. Inspect and clear combustion air inlet — remove any debris or insect nests
  2. Pull inducer compartment cover and listen for inducer motor — it should be audible during startup
  3. Check AFS pressure tubing for kinks or disconnection
  4. Test AFS switch continuity — should close when inducer runs

Verify Before Repair

SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.