Pentair E06: Sensor Failure

Pentair E06 reference for MasterTemp / Max-E-Therm Gas Heater: likely causes, next checks, and manual-verification reminders for pool service techs.

Pentair MasterTemp / Max-E-Therm Gas Heater MEDIUM Certified tech recommended

What It Means

Sensor Failure

Likely Causes

Next Checks

  1. Check thermistor resistance — should be ~10kΩ at 25°C (77°F)
  2. Inspect wiring harness for pinch or corrosion
  3. Replace thermistor if out of spec
  4. Check for moisture ingress in control compartment

Verify Before Repair

SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.