Pentair E01: Ignition Failure

Pentair E01 reference for MasterTemp / Max-E-Therm Gas Heater: likely causes, next checks, and manual-verification reminders for pool service techs.

Pentair MasterTemp / Max-E-Therm Gas Heater HIGH Certified tech recommended

What It Means

Ignition Failure

Likely Causes

Next Checks

  1. Check gas shutoff valve is open
  2. Verify gas pressure (3.5" WC natural, 10" LP at manifold)
  3. Inspect HSI element — should glow orange, replace if cracked
  4. Clean flame rod with emery cloth
  5. Check for multiple ignition lockout (will require manual reset)

Verify Before Repair

SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.