What It Means
Valve Actuator Not Moving
Likely Causes
- Actuator toggle switch off or in wrong position
- 24VAC missing
- Cam/limit switch failed
- Valve body seized
Next Checks
- Check actuator toggle switch and assigned valve circuit
- Test 24VAC at actuator cable when commanded
- Remove actuator and manually turn valve to confirm it is not seized
- Adjust cams/limit switches only after marking original position
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.