What It Means
IntelliFlo / IntelliFlo3 No Communication
Likely Causes
- RS-485 polarity or connection fault
- Pump address mismatch
- Pump not on constant power
- Automation cable disconnected at drive
Next Checks
- Give pump constant line power and let automation control speed by data
- Check RS-485 wiring at pump and automation board
- Reset/reassign pump address if needed
- If display says Display Not Active, that can be normal under automation control
Verify Before Repair