Pentair LIGHT-CIRCUIT: Light Circuit Not Responding

Pentair LIGHT-CIRCUIT reference for Automation - IntelliCenter / EasyTouch / IntelliTouch: likely causes, next checks, and manual-verification reminders for pool service techs.

Pentair Automation - IntelliCenter / EasyTouch / IntelliTouch MEDIUM

What It Means

Light Circuit Not Responding

Likely Causes

Next Checks

  1. Verify circuit assignment in IntelliCenter/EasyTouch
  2. Listen/measure relay output when command is pressed
  3. Check transformer primary and secondary voltage
  4. Reset GFCI and inspect load if it trips again

Verify Before Repair

SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.

SplashLens is independent and is not affiliated with Pentair or other equipment manufacturers.