What It Means
Salt Cell Communication Error
Likely Causes
- RS-485 cable fault between IntelliTouch and IntelliChlor SCG
- IntelliChlor cell or power center failure
- Programming not assigned
Next Checks
- Check RS-485 data cable between IntelliTouch output board and IntelliChlor power center
- Verify IntelliChlor is assigned in IntelliTouch programming
- Test IntelliChlor independently — power center should show diagnostic lights
Verify Before Repair