What It Means
Communication / Board Fault
Likely Causes
- Control board failure
- Display cable loose
- Moisture ingress on board
Next Checks
- Check display ribbon cable at both connectors
- Inspect control board for burn marks or moisture
- If board appears clean: replace control board
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.
SplashLens is independent and is not affiliated with Jandy / Zodiac or other equipment manufacturers.
Use SplashLens At The Pad
Manual error-code lookup works after the app has loaded once. AI scan features require internet and should be treated as a second set of eyes.