What It Means
Gas Valve Fault
Likely Causes
- Gas valve coil open or shorted
- 24V not reaching gas valve
- Gas valve failed mechanically closed
Next Checks
- Measure 24VAC at gas valve terminals during startup — no voltage = control board issue
- Test gas valve coil resistance (typically 20–50Ω) — open or shorted = replace valve
- Do not bypass gas valve
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.
SplashLens is independent and is not affiliated with Jandy / Zodiac or other equipment manufacturers.