Jandy / Zodiac No Comms: Communication Loss

Jandy / Zodiac No Comms reference for iAqualink Automation: likely causes, next checks, and manual-verification reminders for pool service techs.

Jandy / Zodiac iAqualink Automation HIGH Certified tech recommended

What It Means

Communication Loss

Likely Causes

Next Checks

  1. Check RS-485 data cable from main board to sub-panels — verify wire order
  2. Inspect DIP switch addresses on all sub-panels (must be unique, must match programming)
  3. Cycle power to controller and all sub-panels
  4. Check all terminal block wire connections for loose strands

Verify Before Repair

SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.