What It Means
AquaPure / Salt System Offline
Likely Causes
- AquaPure board not powered
- RS-485 wiring fault
- Cell/controller not assigned
- Blown fuse or failed board
Next Checks
- Check AquaPure power and fuse
- Inspect RS-485 wiring at power center
- Verify salt system is enabled/assigned in AquaLink
- Confirm cell diagnostics at AquaPure panel before replacing automation board
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.