What It Means
Communication Fault
Likely Causes
- IntelliFlo not communicating with automation system (EasyTouch, IntelliCenter, etc.)
- RS-485 wiring issue
- Incorrect address DIP switch settings
- Automation system re-pairing needed
Next Checks
- Check RS-485 data cable wiring (A/B polarity and shield grounding)
- Verify pump address DIP switches match automation system address assignment
- Re-pair pump in automation system software (EasyTouch / IntelliCenter setup menu)
- Test RS-485 cable continuity — max run ~4,000 ft at 9600 baud