What It Means
ColorLogic Wrong Color / Out Of Sync
Likely Causes
- Power-cycle color mode out of sequence
- Mixed ColorLogic generations or incompatible mode
- Light not set to the same control mode as Omni/ProLogic
- Long wire run causing voltage drop
Next Checks
- Power all lights off for 30 seconds, then restart the selected show/color together
- Verify all fixtures are set to the same ColorLogic/Universal/Omni Direct mode
- In Omni systems, confirm the light type and zone are assigned correctly
- Measure voltage under load at the junction box; correct undersized wire or transformer capacity issues
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.
SplashLens is independent and is not affiliated with Hayward or other equipment manufacturers.
Use SplashLens At The Pad
Manual error-code lookup works after the app has loaded once. AI scan features require internet and should be treated as a second set of eyes.