SplashLens / Hayward / Lighting - ColorLogic / CrystaLogic

Hayward LIGHT-NO-POWER: Light Will Not Turn On

Hayward LIGHT-NO-POWER reference for Lighting - ColorLogic / CrystaLogic: likely causes, next checks, and manual-verification reminders for pool service techs.

Hayward Lighting - ColorLogic / CrystaLogic HIGH Certified tech recommended

What It Means

Light Will Not Turn On

Likely Causes

Next Checks

  1. Reset GFCI and confirm breaker holds
  2. Verify transformer primary voltage and 12-15VAC secondary output
  3. Check automation relay output when light circuit is commanded on
  4. Inspect junction box and cord connections for corrosion or water intrusion
  5. If voltage is present at fixture and light stays dark, fixture/driver failure is likely

Verify Before Repair

SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.

SplashLens is independent and is not affiliated with Hayward or other equipment manufacturers.

Use SplashLens At The Pad

Manual error-code lookup works after the app has loaded once. AI scan features require internet and should be treated as a second set of eyes.