What It Means
Valve Actuator Does Not Move From Automation
Likely Causes
- Actuator toggle switch off
- Cam switch at limit
- 24VAC missing
- Aux/valve assignment wrong
- Actuator motor failed
Next Checks
- Check actuator toggle switch and listen for motor
- Verify 24VAC at actuator command
- Confirm valve assignment in controller
- Mark cam positions before adjustment
- Replace actuator only after power and assignment are verified
Verify Before Repair
SplashLens is a field reference, not a repair guarantee. Confirm the visible code, exact model, and current manufacturer procedure before replacing parts, bypassing safeties, or quoting a customer.